Filter Results By:

Products

Applications

Manufacturers

Showing results: 361 - 375 of 403 items found.

  • Multi Channel Optical Fibre Verification

    LXinstruments GmbH

    The multi-channel optical fibre test system is used in the development and qualification of single mode optical fibres. The fibres are exposed to environmental influences in a climatic chamber in order to analyse the data on insertion loss and reflection. In addition, the current temperature in the climatic chamber is documented. Insertion loss measurement is performed with the help of an optical power meter, laser sources and optical switches. An Optical Time Domain Reflectometer (OTDR) from Exfo is used for the reflection measurements. The system was designed for the simultaneous characterization of 15 sample fibres and one reference fibre.

  • Arc Ingintion Tester

    SCR ELEKTRONIKS

    The product is designed to carry out Arc Ignition Test as per IS/IEC 60947-1 Clause 8.2.1.1.2 (material used for electrical products). The adjustable current source is 230V AC @ 33A. The load is adjusted to get 32.5A at 0.5 power factor. Included on control unit are Digital Voltmeter, Digital Ammeter, Digital Power Factor Meter and Micro Controller based programmable Sequence Timer with LCD display for display & setting. The arrangement is made to mount the test piece with electrodes as per the specification given in the standard.

  • Dual Mobile Comm DC Source w/ Battery Emulation

    66319B - Keysight Technologies

    The Keysight Mobile Communications DC Source 663xx series offers several features ideal for testing wireless and battery powered devices. Excellent voltage transient response ensures maximum test-system throughput by minimizing device shutdowns due to significant voltage drops in the test wiring. Built-in advanced measurement system to accurately measure battery current drains when the device operates in different modes and a Keysight-developed feature that enables cellular telephone manufacturers to detect permanently and intermittently open-sense wire connections. The Keysight 66319B dual output mobile communications dc source provides two outputs for testing both the main battery power and the battery charger circuitry, allowing customers to test phones and chargers with the same equipment. This feature helps save on rack space (2 outputs in a rack box) and eliminates the need for two separate power supplies.

  • High-Density Precision SMU (10 PA, 30 V)

    PZ2131A - Keysight Technologies

    The Keysight PZ2131A is a high-channel density precision source / measure unit (SMU) having 5 channels per module and saving space for a wide range of applications requiring numerous precision power supplies. The narrow-pulse function and fast Digitizer Mode allow the PZ2131A to expand the conventional static DC measurements to emerging dynamic measurements. Its seamless current measurement ranging function eliminates the time it takes to change the range and expands the dynamic range to cover multiple measurement ranges, which reduces test duration. These capabilities make the PZ2131A suitable for applications that require numerous precision power supplies, such as semiconductor reliability tests and integrated circuit (IC) tests. The Keysight PX0107A low noise filter adapter lowers its voltage source noise level, which makes the PZ2131A suitable for noise-sensitive applications such as quantum computing as well.

  • Analog Input Products

    Acces I/O Products, Inc.

    Analog input boards are useful for measuring variably changing conditions in the real world. When we want to measure these variably changing conditions, we need analog inputs to convert these changing real world conditions to changing electrical quantities. For example, monitoring the temperature inside a wood kiln, or the water pressure on the output of a pump, or the heart rate of a medical patient. In each of these cases, you can use one of our analog input devices to convert the electrical data from a sensor or transducer into binary data that can then be used by your computer. The device that converts this data is known as an analog to digital converter (abbreviated ADC, A/D, or A to D). An analog input is a measurable electrical signal with a defined range. The analog input changes continuously in a definable manner in relation to the measured property. This data is very useful for process monitoring, process control, or simple monitoring / data collection and acquisition. ACCES' analog input boards amplify and multiplex input signals from thermocouples, strain gauges, accelerometers, photo sensors, flowmeters, RTDs, thermistors, voltage sources, millivolt sources, and current sources, just to name a few.

  • Electrical Safety Test Equipment

    IBEKO Power AB

    Making a product “safe” requires an understanding of “hazards” that exist in each electrical product. Electrical shock is one of the four fundamental hazards. Because of that, it must be a part of any product electrical safety evaluation. Even though a product requires an electrical power source and uses electrical or electronic components, it should not present an electrical shock hazard to the user.Ground bond or earth continuity testing prevents electrical shock hazards. Similarly to a fault to earth, test instruments generate a high current. The standard requires that the resistance between protective earth and any conductive surface on the equipment does not exceed 0,1 Ohm. The test is performed by applying a DC current between the conductive surface and protective earth. By measuring the voltage drop, it calculates the resistance.RMO-E instruments are ideal for testing the protective bonding (grounding) of equipment following the standard IEC 61010-1. Applying current up to the value of 100 A and the ability to provide in the Contin menu (continuous operation) test current for the pre-set test duration (equal or exceeding 1 min) gives a user a possibility to easily check the protective bonding/grounding of the equipment. The full load voltage of 12 V assures proper measurement and accurate result. Finally, an instrument displays pass/fail classification according to user-preset parameters.

  • Load Cell Power Supply

    MODEL PSMR - Transducer Techniques, Inc

    The PSM-R is a self contained AC power bridge excitation supply. This device consists of a low interwinding capacitance AC transformer and a high stability adjustable linear regulator designed specifically for driving transducer bridges. DC excitation is adjustable from 4 to 15 volts output and is capable of supplying 0 to 150 mA in output current. It features remote sensing to eliminate line drop errors and very low noise. It can also be used as a high quality voltage source or reference in many applications. AC input requirements are 105 to 125 VAC at 60 Hz.

  • 2-Quadrant Source/Measure Unit for Functional Test, 20 V, 1 A or 6 V, 3 A, 20 W

    N6782A - Keysight Technologies

    The Keysight N6782A is a source/measure unit (SMU) designed specifically for advanced functional testing of a device. The ability to modulate the output up to 100 kHz along with capability to source and sink current (2-quadrant operation) makes the N6782A a perfect fit for advanced functional test of a variety of devices such as DC/DC converters, power management units, power amplifiers, and power management ICs. The input stage of the DUT can be stimulated by the fast sourcing and waveform capabilities. While the output stage can be loaded down and measured with the electronic load capabilities, providing a total test solution.

  • Near Field Probes 30 MHz up to 3 GHz

    RF6 set - Langer EMV-Technik GmbH

    The RF6 near field probe set consists of 2 passive magnetic field probes and 2 passive E field probes for measurements in the development phase of the E-field and magnetic field in the range from 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF6 set allow a step by step localization of interference sources of the RF magnetic field and RF-E-field on an assembly. From a larger distance the electromagnetic interference is detected by RF-R 50-1 for the magnetic field and by RF-E 02 for the E-field. The RF-B 3-2 and RF-E 10 probes with their higher resolution can more presicely detect the interference sources of the magnetic field and the E-field. Field orientation and field distribution on an electronic assembly can be detected by special guidiance of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.

  • Multifunction Calibrator 15 ppm Basic Accuracy

    MC142 - Powertek LLC

    Multifunction calibrator MC142 is a precision voltage, current and power calibration source serving as a measurement standard in calibration laboratories and production lines; where verification of electrical measurement equipment & sensors is required. It can be used for calibration and adjustment of meters measuring voltage, current, power, resistance, capacitance and frequency. Internal harmonic and non-harmonic signals make it possible to test electrical performance of meters using signals with various crest factors. Frequency modes enable selection of frequency, amplitude and duty cycle of the output signal. These are suitable for basic calibration of digital and analog oscilloscopes along with transient recorders. The calibrator is equipped to measure temperature with TC and RTD temperature sensors. Its built-in multimeter can be used independently or simultaneously with the calibrator output. Testing of transducers of various types, regulators and sensors can be performed, without the necessity to use any other measuring instrument.

  • Programmable AC Power Source

    LSP-500VAC - Lisun Electronics Inc.

    • Applied with the AC-DC-AC inverter technology and digital waveform synthesis & waveform feedback technology, low distortion power; • Applied with entire cycle high-precision measurement technology and high-speed sampling technologies, panel of instrument will directly and accurately displays the power output of the voltage, frequency, current, active power and power factor to achieve the integration of the source table; • Applied with SCM control and measurement technology, high intelligence; • Applied with zero output impedance technology, the output equivalent impedance is almost zero and further improve the stability of power supply; • Applied with isolated floating output technology, the power output and input have good isolation, floating output, conducive to make sure power itself safety and operator’s safety; • Perfect voltage, current anomalies and overheating protection, improve the reliability of power supply; • Applied with power limiting technology to avoid strong interference on the power grid and other electrical equipment, while facilitating reliable operation of the power supply itself; • The input voltage can be option via a toggle switch of panel mains 110V/220V; • The initial phase and end phase of the output voltage waveform can be set {0°-359° (±1°)}; • Measurement process can be programmed to control (1 to 50 memory groups, 1 to 9 steps for each memory group);

  • RCD/LOOP/PAT Testers

    Kyoritsu Electrical Instruments Works, Ltd.

    Custom microprocessor controlled for highest accuracy and reliability. 3 LEDs for checking correct wiring status. 0 and 180 degree phase angle switch permits quick tests and consistent readings. Digital read-out of tripping time. Constant current source circuitry ensures that a fluctuating mains voltage does not affect the accuracy of readings. Large custom digital display readout. Visual indication of reversed phase and neutral wiring at socket. Designed to IP54 Rating. Complies with IEC 61557 Test of a large kind of RCD''''s: Standard, Selective, AC and A (DC sensitive breakers)

  • Complete Solution for Developing & Testing Discrete Voltage-Level Interfaces

    M4KDiscrete Module - Excalibur Systems, Inc.

    The M4KDiscrete module provides a complete solution for developing and testing discrete voltage-level interfaces. The M4KDiscrete contains control I/O registers that are memory-mapped and may be accessed in real time. The module supports twenty programmable I/O discretes that can record or control the external discretes that are connected to it. In addition, the module can record changes in the input discrete with an associated time tag via a built-in FIFO. Output discretes are open collector, capable of handling up to 32V with a maximum sink current of 100 mA each. Ordering Information:The user can set each discrete:• Either as input or output.• Either to TTL (0 – 5V) or Avionics (0 – 32V) voltage levels on inputs and• Either enable or disable external debounce on inputsThere is a 4092 Word FIFO (a string of 1023 discrete entries) containing the data and time tags.The M4KDiscrete module is supplied with C drivers, including source code and may be used with Exalt, Excalibur’s Analysis and Laboratory Tools, a Windows monitoring application.

  • Near Field Probes 30 MHz up to 6 GHz

    XF1 set - Langer EMV-Technik GmbH

    The XF1 set of near field probes consists of 4 passive near field probes and one passive E field probe for making measurements in the development phase of the magnetic and electric fields in ranges from 30 MHz to 6 GHz. Due to their integrated impendance matching, the probes are less sensitive in the lower frequency range than the RF type probes. The probe heads of the XF1 set allow for the step by step identification of interference sources of the magnetic field on an electronic assembly. At first, for example the XF-R 400-1 detects the fields which the assembly emits in total. Next, using higher resolution probes the interference sources can be more precisely detected. The E field probe is used for the detection of electric interfering fields near the assemblies. With trained use of the near field probes, field orientation and field distribution can be detected. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They have an internal terminating resistance.

  • PXI Based Multifunction Measurement and ICT Instrument

    PXI-501 - Konrad Technologies GmbH

    The PXI-501 is a multifunction measurement instrument for functional and in-circuit measurements.It combines two parametric measurement units with a digital voltmeter, a high voltage current source and a discharge unit. This powerful combination makes it the ideal instrument for classical analog in-circuit test and manufacturing defect analysis with additional functional test capabilities.With it’s fast sampling rate of up to 4MSps it speeds up measurements and is capable of measuring and generating AC signals up to 100kHz.To enhance the PXI-501 capabilities it can be combined with an ABex TM-501 or an ABex TM-404. The ABex TM-501 enhances the in and output range of the PXI-501. Furthermore, it provides a shunt current measurement upgrade. In combination with the ABex TM-404 it’s a complete in-circuit test solution with 86 channels in one ABex slot. For sure it can be upgraded to 2838 test points in one rack by simply adding additional matrix modules.With the above-mentioned terminal modules, the PXI-501 is able to act as a ABex system controller, so that no additional controller is required in the cassis.

Get Help